ABOUT ASTM F2170

About Astm F2170

About Astm F2170

Blog Article



ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6

When it concerns guaranteeing security in commercial, industrial, and domestic areas, slip resistance testing is a critical factor. At ATTAR (Advanced Technology Testing & Research), we focus on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to assist businesses and property owners reduce dangers and abide by security standards.

With cutting edge equipment such as the pendulum slip test device and moisture meter for concrete, we supply precise and independent slip testing services throughout Australia. Our proficiency covers ASTM F2170 compliance, R Score assessments, P Score tiles, and more, guaranteeing your floors meet the highest security benchmarks.

Why Slip Resistance Testing is Important


Slips and falls are among the leading causes of work environment and public injuries. Appropriate slip testing helps determine dangerous surface areas before mishaps happen. Whether you require damp pendulum test assessments or pendulum test for slip resistance, ATTAR provides accurate results to improve safety.

Key Services Offered by ATTAR


1. Floor Slip Resistance Testing

- Pendulum slip test (AS 4663).
- R Rating and P Rating tiles assessments.
- Independent slip testing services for compliance.

2. Concrete Moisture Testing

- Slab moisture test using innovative moisture meter for concrete.
- ASTM F2170 certified evaluations.
- Concrete slab moisture testing to prevent floor covering failures.

3. Luminance Contrast Testing

- Guarantees exposure for visually impaired individuals.
- Complies with Australian accessibility standards.

4. On-Site & Laboratory Testing

- Slip test maker for precise on-site assessments.
- Wet pendulum test for wet surface slip resistance.

Understanding Slip Resistance Rankings: R Ranking vs. P Score


When carrying out slip resistance testing, two key categories are utilized:.

- R Score (Ramp Test - DIN 51130)
Steps slip resistance under lubricated conditions, commonly utilized in Europe.

- P Ranking (Pendulum Test - AS 4586)
Evaluates dynamic friction using a pendulum test slip resistance maker, commonly adopted in Australia.

ATTAR provides independent slip testing to determine whether your floor covering fulfills the required pendulum rating tiles requirements.

The Significance of Concrete Moisture Testing


Excess moisture in concrete slabs can result in flooring failures, mold development, and adhesive deterioration. Our concrete moisture testing services include:.

> ASTM F2170 certified in-situ relative humidity testing.
> Moisture meter for concrete assessments.
> Slab moisture test to ensure optimum conditions for floor setups.

By spotting moisture issues early, we assist prevent pricey repair work and ensure lasting flooring efficiency.

Luminance Contrast for Ease Of Access Compliance


Proper luminance contrast is vital for visually impaired individuals to browse spaces securely. ATTAR evaluates:.

> Stair edges.
> Door frames.
> Handrails.
> Tactile indications.

Our assessments make sure compliance with Australian Impairment Standards (AS 1428.1).

Why Choose ATTAR for Slip Resistance & Moisture Testing?


> NATA Accredited (where suitable).
> Advanced Testing Equipment (pendulum slip test, moisture meters).
> Nationwide Service Protection.
> Fast & Trusted Reporting.

For professional slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.

Address: 44/48 Rocco Dr, Scoresby Anti Slip Test VIC 3179, Australia.
Phone: +61 1300 139 155.

Typical Applications of Slip Resistance Testing


1. Commercial & Retail Spaces

Shopping center, dining establishments, and offices need safe flooring to prevent consumer and employee injuries. Our pendulum slip test makes sure compliance with safety policies.

2. Industrial & Storage Facility Facilities

High-traffic industrial environments require durable, slip-resistant floor covering. ATTAR's slip testing services assist preserve office safety.

3. Health Care & Aged Care Facilities

Medical facilities and retirement home should decrease slip risks. Our luminance contrast and slip resistance testing guarantee safe movement for patients and staff.

4. Public Facilities

Footpaths, train stations, and government structures need independent slip testing to meet ease of access and security standards.

How ATTAR Carries Out Slip Resistance Testing


Action 1: Surface Area Assessment

We assess floor covering products and conditions (dry, wet, or polluted).

Action 2: Pendulum Slip Test (AS 4663)

Utilizing a slip test machine, we measure the vibrant coefficient of friction (DCOF).

Action 3: Wet Pendulum Test

Simulates slippery conditions to assess real-world slip dangers.

Step 4: Reporting & Compliance Accreditation

In-depth reports with R Rating or P Rating tiles classifications.

The Science Behind Pendulum Slip Testing


The pendulum test slip resistance approach includes a swinging arm with a rubber slider that mimics a foot's movement. The test measures:.

- Slip Prospective Worth (SPV).
- Pendulum ranking tiles category (P0 to P5).

Greater ratings (P4/P5) show better slip resistance.

Moisture Testing for Concrete Floors: Preventing Failures


Moisture-related flooring failures can be expensive. ATTAR's concrete slab moisture testing includes:.

- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete check.
- Slab moisture test information analysis.

Conclusion


ATTAR (Advanced Technology Testing & Research) is Australia's relied on supplier of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast evaluations. With cutting-edge technology like the pendulum slip test and moisture meter for concrete, we deliver accurate, independent, and compliant testing services.

Ensure your property meets safety standards-- contact ATTAR today:.

44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.

By choosing ATTAR, you invest in independent slip testing services, pendulum test slip resistance precision, and long-lasting floor security services. Let us assist you produce much safer, compliant, and moisture-resistant environments.

Report this page